WKUPIS12=DIS, SMRSTS=NO, SMOS=HIGH, SMWS=NO, WKUPIS13=DIS, WKUPIS4=DIS, SMS=NO, LPDBCS1=NO, WKUPIS7=DIS, WKUPIS1=DIS, OSCSEL=RC, WKUPIS0=DIS, WKUPIS8=DIS, WKUPIS15=DIS, WKUPIS11=DIS, WKUPIS3=DIS, LPDBCS0=NO, WKUPIS14=DIS, WKUPIS2=DIS, WKUPIS10=DIS, WKUPIS5=DIS, WKUPIS9=DIS, WKUPS=NO, BODRSTS=NO, WKUPIS6=DIS
Supply Controller Status Register
WKUPS | WKUP Wake Up Status 0 (NO): no wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake up due to the assertion of the WKUP pins has occurred since the last read of SUPC_SR. |
SMWS | Supply Monitor Detection Wake Up Status 0 (NO): no wake up due to a supply monitor detection has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake up due to a supply monitor detection has occurred since the last read of SUPC_SR. |
BODRSTS | Brownout Detector Reset Status 0 (NO): no core brownout rising edge event has been detected since the last read of the SUPC_SR. 1 (PRESENT): at least one brownout output rising edge event has been detected since the last read of the SUPC_SR. |
SMRSTS | Supply Monitor Reset Status 0 (NO): no supply monitor detection has generated a core reset since the last read of the SUPC_SR. 1 (PRESENT): at least one supply monitor detection has generated a core reset since the last read of the SUPC_SR. |
SMS | Supply Monitor Status 0 (NO): no supply monitor detection since the last read of SUPC_SR. 1 (PRESENT): at least one supply monitor detection since the last read of SUPC_SR. |
SMOS | Supply Monitor Output Status 0 (HIGH): the supply monitor detected VDDIO higher than its threshold at its last measurement. 1 (LOW): the supply monitor detected VDDIO lower than its threshold at its last measurement. |
OSCSEL | 32-kHz Oscillator Selection Status 0 (RC): the slow clock, SLCK is generated by the embedded 32-kHz RC oscillator. 1 (CRYST): the slow clock, SLCK is generated by the 32-kHz crystal oscillator. |
LPDBCS0 | Low Power Debouncer Wake Up Status on WKUP0 0 (NO): no wake up due to the assertion of the WKUP0 pin has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake up due to the assertion of the WKUP0 pin has occurred since the last read of SUPC_SR. |
LPDBCS1 | Low Power Debouncer Wake Up Status on WKUP1 0 (NO): no wake up due to the assertion of the WKUP1 pin has occurred since the last read of SUPC_SR. 1 (PRESENT): at least one wake up due to the assertion of the WKUP1 pin has occurred since the last read of SUPC_SR. |
WKUPIS0 | WKUP Input Status 0 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS1 | WKUP Input Status 1 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS2 | WKUP Input Status 2 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS3 | WKUP Input Status 3 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS4 | WKUP Input Status 4 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS5 | WKUP Input Status 5 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS6 | WKUP Input Status 6 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS7 | WKUP Input Status 7 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS8 | WKUP Input Status 8 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS9 | WKUP Input Status 9 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS10 | WKUP Input Status 10 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS11 | WKUP Input Status 11 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS12 | WKUP Input Status 12 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS13 | WKUP Input Status 13 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS14 | WKUP Input Status 14 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |
WKUPIS15 | WKUP Input Status 15 0 (DIS): the corresponding wake-up input is disabled, or was inactive at the time the debouncer triggered a wake up event. 1 (EN): the corresponding wake-up input was active at the time the debouncer triggered a wake up event. |