TRAPE=value1, CMOD=value1, TRPSE=value1, TSSM=value1, DITHE=value1, TCM=value1, ECM=value1, EMS=value1, SCE=value1, CAPC=value1, ENDM=value1, MCME=value1, EMT=value1, TRPSW=value1, FPE=value1, DIM=value1, STRM=value1, CCS=value1
Slice Timer Control
TCM | Timer Counting Mode 0 (value1): Edge aligned mode 1 (value2): Center aligned mode |
TSSM | Timer Single Shot Mode 0 (value1): Single shot mode is disabled 1 (value2): Single shot mode is enabled |
CLST | Shadow Transfer on Clear |
CMOD | Capture Compare Mode 0 (value1): Compare Mode 1 (value2): Capture Mode |
ECM | Extended Capture Mode 0 (value1): Normal Capture Mode 1 (value2): Extended Capture Mode |
CAPC | Clear on Capture Control 0 (value1): Timer is never cleared on a capture event 1 (value2): Timer is cleared on a capture event into capture registers 2 and 3. (When SCE = 1#, Timer is always cleared in a capture event) 2 (value3): Timer is cleared on a capture event into capture registers 0 and 1. (When SCE = 1#, Timer is always cleared in a capture event) 3 (value4): Timer is always cleared in a capture event. |
ENDM | Extended Stop Function Control 0 (value1): Clears the timer run bit only (default stop) 1 (value2): Clears the timer only (flush) 2 (value3): Clears the timer and run bit (flush/stop) |
STRM | Extended Start Function Control 0 (value1): Sets run bit only (default start) 1 (value2): Clears the timer and sets run bit (flush/start) |
SCE | Equal Capture Event enable 0 (value1): CCycapt0 and CCycapt1 used for capture trigger 1 (value2): Only CCycapt1 used for capture trigger |
CCS | Continuous Capture Enable 0 (value1): The capture into a specific capture register is done with the rules linked with the full flags 1 (value2): The capture into the capture registers is always done regardless of the full flag |
DITHE | Dither Enable 0 (value1): Dither is disabled 1 (value2): Dither is applied to the Period 2 (value3): Dither is applied to the Compare 3 (value4): Dither is applied to the Period and Compare |
DIM | Dither input selector 0 (value1): Slice is using its own dither unit 1 (value2): Slice is connected to the dither unit of slice 0. |
FPE | Floating Prescaler enable 0 (value1): Floating prescaler mode is disabled 1 (value2): Floating prescaler mode is enabled |
TRAPE | TRAP enable 0 (value1): TRAP functionality has no effect on the output 1 (value2): TRAP functionality affects the output |
TRPSE | TRAP Synchronization Enable 0 (value1): Exiting from TRAP state isn’t synchronized with the PWM signal 1 (value2): Exiting from TRAP state is synchronized with the PWM signal |
TRPSW | TRAP State Clear Control 0 (value1): The slice exits the TRAP state automatically when the TRAP condition is not present 1 (value2): The TRAP state can only be exited by a SW request. |
EMS | External Modulation Synchronization 0 (value1): External Modulation functionality is not synchronized with the PWM signal 1 (value2): External Modulation functionality is synchronized with the PWM signal |
EMT | External Modulation Type 0 (value1): External Modulation functionality is clearing the CC4yST bit. 1 (value2): External Modulation functionality is gating the outputs. |
MCME | Multi Channel Mode Enable 0 (value1): Multi Channel Mode is disabled 1 (value2): Multi Channel Mode is enabled |