Infineon /IMC300A /SCU_ANALOG /ANAOSCHPCTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as ANAOSCHPCTRL

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)SHBY 0 (value1)GAINSEL 0 (value1)MODE 0 (value1)HYSCTRL

GAINSEL=value1, HYSCTRL=value1, MODE=value1, SHBY=value1

Description

OSC_HP Control Register

Fields

SHBY

Shaper Bypass Mode

0 (value1): The shaper is not bypassed

1 (value2): The shaper is bypassed

GAINSEL

OSC_HP Oscillator Gain Selection

0 (value1): Gain control is configured for frequencies from 4 MHz to y1 MHz

1 (value2): Gain control is configured for frequencies from 4 MHz to y2 MHz

2 (value3): Gain control is configured for frequencies from 4 MHz to 20 MHz

MODE

OSC_HP Oscillator Mode

0 (value1): Oscillator Mode with shaper enabled

1 (value2): External Clock Input Mode with shaper enabled

2 (value3): Oscillator Mode with shaper disabled

3 (value4): Oscillator is in power down mode with shaper disabled

HYSCTRL

Shaper Hystersis Mode

0 (value1): External clock frequency below 20MHz.

1 (value2): External clock frequency above 20MHz