DSEL=value1, SFSEL=value1, CM=value1, DPOL=value1, DSEN=value1, DFEN=value1, DXS=value1, INSW=value1
Input Control Register 3
DSEL | Data Selection for Input Signal 0 (value1): The data input DX3A is selected. 1 (value2): The data input DX3B is selected. 2 (value3): The data input DX3C is selected. 3 (value4): The data input DX3D is selected. 4 (value5): The data input DX3E is selected. 5 (value6): The data input DX3F is selected. 6 (value7): The data input DX3G is selected. 7 (value8): The data input of DX3 is always 1. |
INSW | Input Switch 0 (value1): DX3 input of the data shift unit is controlled by the protocol pre-processor. 1 (value2): DX3 input of the data shift unit is connected to the selected data input line. |
DFEN | Digital Filter Enable 0 (value1): The DX3 input signal is not digitally filtered. 1 (value2): The DX3 input signal is digitally filtered. |
DSEN | Data Synchronization Enable 0 (value1): The un-synchronized signal can be taken as DX3 input for the data shift unit. 1 (value2): The synchronized signal can be taken as DX3 input for the data shift unit. |
DPOL | Data Polarity for DXn 0 (value1): The DX3 input signal is not inverted. 1 (value2): The DX3 input signal is inverted. |
SFSEL | Sampling Frequency Selection 0 (value1): The DX3 sampling frequency is fPERIPH. 1 (value2): The DX3 sampling frequency is fFD. |
CM | Combination Mode 0 (value1): The DX3 trigger activation is disabled. 1 (value2): A rising edge activates DX3T. 2 (value3): A falling edge activates DX3T. 3 (value4): Both edges activate DX3T. |
DXS | Synchronized Data Value 0 (value1): The current value of DX3S is 0. 1 (value2): The current value of DX3S is 1. |