ST_MODE=value1, MPS=value1, ROTVEC=value1, MODE=value1, X_USIGN=value1
CORDIC Control Register
ST | Start Calculation |
MODE | Operating Mode 0 (value1): Linear Mode 1 (value2): Circular Mode (default) 3 (value4): Hyperbolic Mode |
ROTVEC | Rotation Vectoring Selection 0 (value1): Vectoring Mode (default) 1 (value2): Rotation Mode |
ST_MODE | Start Method 0 (value1): Auto start of calculation after write access to X parameter data register CORDX(default). 1 (value2): Start calculation only after bit ST is set |
X_USIGN | Result Data Format for X in Circular Vectoring Mode 0 (value1): Signed, twos complement 1 (value2): Unsigned (default) |
MPS | X and Y Magnitude Prescaler 0 (value1): Divide by 1 1 (value2): Divide by 2 (default) 2 (value3): Divide by 4 3 (value4): Reserved, retain the last MPS setting |