Infineon /XMC1400 /SCU_CLK /OSCCSR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as OSCCSR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)OSC2L 0 (value1)OSC2H 0 (value1)DCO1PD 0 (value1)OWDRES 0 (value1)OWDEN 0 (value1)XOWDRES 0 (value1)XOWDEN

XOWDEN=value1, XOWDRES=value1, OWDRES=value1, DCO1PD=value1, OSC2H=value1, OSC2L=value1, OWDEN=value1

Description

Oscillator Control and Status Register

Fields

OSC2L

Oscillator Valid Low Status Bit

0 (value1): The OSC frequency is usable

1 (value2): The OSC frequency is not usable. Frequency is too low.

OSC2H

Oscillator Valid High Status Bit

0 (value1): The OSC frequency is usable

1 (value2): The OSC frequency is not usable. Frequency is too high.

DCO1PD

DCO1 Power down

0 (value1): DCO1 is not power down

1 (value2): DCO1 power down.

OWDRES

Oscillator Watchdog Reset

0 (value1): The Oscillator Watchdog is not cleared and remains active

1 (value2): The Oscillator Watchdog is cleared and restarted. The OSC2L and OSC2H flag will be held in the last value until it is updated after 3 standby clock cycles.

OWDEN

Oscillator Watchdog Enable

0 (value1): The Oscillator Watchdog is disabled

1 (value2): The Oscillator Watchdog is enabled

XOWDRES

XTAL Oscillator Watchdog Reset

0 (value1): The Oscillator Watchdog is not cleared and remains active

1 (value2): The Oscillator Watchdog is cleared and restarted.

XOWDEN

XTAL Oscillator Watchdog Enable

0 (value1): The XTAL Oscillator Watchdog is disabled

1 (value2): The XTAL Oscillator Watchdog is enabled