H2DSTE=value1, H1DSTE=value1, H3STE=value1, H0DSTE=value1, H0STE=value1, H3DSTE=value1, H2STE=value1, H1STE=value1
Global HRC shadow transfer status
H0STE | HRC0 high resolution values shadow transfer status 0 (value1): No shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values 1 (value2): Shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values |
H0DSTE | HRC0 dead time value shadow transfer status 0 (value1): No shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values 1 (value2): Shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values |
H1STE | HRC1 high resolution values shadow transfer status 0 (value1): No shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values 1 (value2): Shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values |
H1DSTE | HRC1 dead time value shadow transfer status 0 (value1): No shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values 1 (value2): Shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values |
H2STE | HRC2 high resolution values shadow transfer status 0 (value1): No shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values 1 (value2): Shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values |
H2DSTE | HRC2 dead time value shadow transfer status 0 (value1): No shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values 1 (value2): Shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values |
H3STE | HRC3 high resolution values shadow transfer status 0 (value1): No shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values 1 (value2): Shadow transfer pending for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values |
H3DSTE | HRC3 dead time value shadow transfer status 0 (value1): No shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values 1 (value2): Shadow transfer pending for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values |