SVIS=value1, SCS=value1
External input selection
SVIS | Value Selector input selection 0 (value1): HRPWMx.SyIA 1 (value2): HRPWMx.SyIB 2 (value3): HRPWMx.SyIC 3 (value4): HRPWMx.SyID 4 (value5): HRPWMx.SyIE 5 (value6): HRPWMx.SyIF 6 (value7): HRPWMx.SyIG 7 (value8): HRPWMx.SyIH 8 (value9): HRPWMx.SyII 9 (value10): HRPWMx.SyIJ 10 (value11): HRPWMx.SyIK 11 (value12): HRPWMx.SyIL 12 (value13): HRPWMx.SyIM 13 (value14): HRPWMx.SyIN 14 (value15): HRPWMx.SyIO 15 (value16): HRPWMx.SyIP |
STRIS | Slope generation start control input selection |
STPIS | Slope generation stop control input selection |
TRGIS | External conversion trigger input selection |
STIS | External shadow request enable input selection |
SCS | Slope generation clock selection 0 (value1): HRPWMx.MCLK (Module clock is used) 1 (value2): HRPWMx.ECLKA (External clock is used) 2 (value3): HRPWMx.ECLKB (External clock is used) 3 (value4): HRPWMx.ECLKC (External clock is used) |