Infineon /XMC4200 /HRPWM0_HRC0 /GC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as GC

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (value1)HRM0 0 (value1)HRM1 0 (value1)DTE 0 (value1)TR0E 0 (value1)TR1E 0 (value1)STC 0 (value1)DSTC 0 (value1)OCS0 0 (value1)OCS1 0 (value1)DTUS

DTE=value1, STC=value1, TR0E=value1, OCS0=value1, TR1E=value1, DTUS=value1, OCS1=value1, HRM0=value1, HRM1=value1, DSTC=value1

Description

HRC mode configuration

Fields

HRM0

HRCy high resolution mode configuration for source selector 0

0 (value1): Rising edge high resolution signal positioning enabled

1 (value2): Falling edge high resolution signal positioning enabled

2 (value3): Both edges high resolution signal positioning is enabled

3 (value4): No high resolution positioning

HRM1

HRCy high resolution mode configuration for source selector 1

0 (value1): Rising edge high resolution signal positioning enabled

1 (value2): Falling edge high resolution signal positioning enabled

2 (value3): Both edges high resolution signal positioning is enabled

3 (value4): No high resolution positioning

DTE

HRCy dead time enable

0 (value1): Dead time insertion is disabled

1 (value2): Dead time insertion is enabled

TR0E

HRCy trap enable

0 (value1): Trap function for HRPWMx.HROUTy0 is disabled

1 (value2): Trap function for HRPWMx.HROUTy0 is enabled

TR1E

HRCy complementary trap enable

0 (value1): Trap function for HRPWMx.HROUTy1 is disabled

1 (value2): Trap function for HRPWMx.HROUTy1 is enabled

STC

HRCy shadow transfer configuration

0 (value1): HRCy shadow transfer enable for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values is not linked with the specific Capture/Compare Unit timer.

1 (value2): HRCy shadow transfer enable for HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . values is linked with the specific Capture/Compare Unit timer.

DSTC

HRCy dead time shadow transfer configuration

0 (value1): HRCy shadow transfer enable for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values is not linked with the specific Capture/Compare Unit timer.

1 (value2): HRCy shadow transfer enable for HRCyDCRThis register holds the dead time value that is going to be inserted whenever a rising transition on the output latch is sensed. and HRCyDCFThis register holds the dead time value that is going to be inserted whenever a falling transition on the output latch is sensed. values is linked with the specific Capture/Compare Unit timer.

OCS0

HRPWMx.OUTy0 channel selector

0 (value1): HRPWMx.OUTy0 is connected to the latch Q channel

1 (value2): HRPWMx.OUTy0 is connected to the latch Qn channel

OCS1

HRPWMx.OUTy1 channel selector

0 (value1): HRPWMx.OUTy1 is connected to the latch Qn channel

1 (value2): HRPWMx.OUTy1 is connected to the latch Q channel

DTUS

Dead Time update trigger selector

0 (value1): The update of the values is done with the trigger generated by the timers. This is the same trigger that is used to update the HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, …

1 (value2): The update of the dead time values is done when the dead time counter is not running, independently of the HRCyCR1This register holds the value for the rising edge high resolution signal placement. the update of this value should be done via the associated shadow register, . and HRCyCR2This register holds the value for the falling edge high resolution signal placement. the update of this value should be done via the associated shadow register, . registers.