Description

HRC timer selection

Fields

TSEL0

Source Selector 0 Timer connection

0 (value1): Source Selector 0 is connected to Capture/Compare Unit Timer 0 (CCST0 can be used)

1 (value2): Source Selector 0 is connected to Capture/Compare Unit Timer 1 (CCST1 can be used)

2 (value3): Source Selector 0 is connected to Capture/Compare Unit Timer 2 (CCST2 can be used)

3 (value4): Source Selector 0 is connected to Capture/Compare Unit Timer 3 (CCST3 can be used)

TSEL1

Source Selector 1 Timer connection

0 (value1): Source Selector 1 is connected to Capture/Compare Unit Timer 0 (CCST0 can be used)

1 (value2): Source Selector 1 is connected to Capture/Compare Unit Timer 1 (CCST1 can be used)

2 (value3): Source Selector 1 is connected to Capture/Compare Unit Timer 2 (CCST2 can be used)

3 (value4): Source Selector 1 is connected to Capture/Compare Unit Timer 3 (CCST3 can be used)

TS0E

Source selector 0 TRAP enable

0 (value1): TRAP signal generated from the Timer connected to Source Selector 0 is disabled.

1 (value2): TRAP signal generated from the Timer connected to Source Selector 0 is enabled.

TS1E

Source selector 1 TRAP enable

0 (value1): TRAP signal generated from the Timer connected to Source Selector 1 is disabled.

1 (value2): TRAP signal generated from the Timer connected to Source Selector 1 is enabled.