TSEL1=value1, TS0E=value1, TS1E=value1, TSEL0=value1
HRC timer selection
TSEL0 | Source Selector 0 Timer connection 0 (value1): Source Selector 0 is connected to Capture/Compare Unit Timer 0 (CCST0 can be used) 1 (value2): Source Selector 0 is connected to Capture/Compare Unit Timer 1 (CCST1 can be used) 2 (value3): Source Selector 0 is connected to Capture/Compare Unit Timer 2 (CCST2 can be used) 3 (value4): Source Selector 0 is connected to Capture/Compare Unit Timer 3 (CCST3 can be used) |
TSEL1 | Source Selector 1 Timer connection 0 (value1): Source Selector 1 is connected to Capture/Compare Unit Timer 0 (CCST0 can be used) 1 (value2): Source Selector 1 is connected to Capture/Compare Unit Timer 1 (CCST1 can be used) 2 (value3): Source Selector 1 is connected to Capture/Compare Unit Timer 2 (CCST2 can be used) 3 (value4): Source Selector 1 is connected to Capture/Compare Unit Timer 3 (CCST3 can be used) |
TS0E | Source selector 0 TRAP enable 0 (value1): TRAP signal generated from the Timer connected to Source Selector 0 is disabled. 1 (value2): TRAP signal generated from the Timer connected to Source Selector 0 is enabled. |