TRIGSEL=value1, CMPEN=value1
Analog Wake-up Configuration Register
CMPEN | Compare Enable for Input Selection 0 (value1): Comparator permanently in power down 1 (value2): Comparator activated for VBAT input 2 (value3): Comparator activated for HIB_IO_0 input 4 (value4): Comparator activated for HIB_IO_1 input |
TRIGSEL | Analog Compare Trigger Select 0 (value1): Sub-second interval counter 1 (value2): RTC alarm event 2 (value3): RTC periodic event 3 (value4): On digital WKUP input positive edge event 5 (value5): On digital WKUP input negative edge event 6 (value6): Continuous measurement 7 (value7): Single-shot on software request |
CONVDEL | Conversion Delay |
INTERVCNT | Sub-second Interval Counter |
SETTLECNT | LPAC Settle Time Counter |