ULPWDGEN=Const_0, HIBIO1POL=Const_0, HIBIO1SEL=Const_0000, HIBIO0SEL=Const_0000, WKUPSEL=Const_0, STDBYSEL=Const_0, RCS=Const_0, HIB=Const_0, WKPEP=Const_0, WKPEN=Const_0, HIBIO0POL=Const_0, RTCE=Const_0, GPI0SEL=Const_0
Hibernate Domain Control Register
WKPEP | Wake-Up on Pin Event Positive Edge Enable 0 (Const_0): Wake-up event disabled 1 (Const_1): Wake-up event enabled |
WKPEN | Wake-up on Pin Event Negative Edge Enable 0 (Const_0): Wake-up event disabled 1 (Const_1): Wake-up event enabled |
RTCE | Wake-up on RTC Event Enable 0 (Const_0): Wake-up event disabled 1 (Const_1): Wake-up event enabled |
ULPWDGEN | ULP WDG Alarm Enable 0 (Const_0): Wake-up event disabled 1 (Const_1): Wake-up event enabled |
HIB | Hibernate Request Value Set 0 (Const_0): External hibernate request inactive 1 (Const_1): External hibernate request active |
RCS | fRTC Clock Selection 0 (Const_0): fOSI selected 1 (Const_1): fULP selected |
STDBYSEL | fSTDBY Clock Selection 0 (Const_0): fOSI selected 1 (Const_1): fULP selected |
WKUPSEL | Wake-Up from Hibernate Trigger Input Selection 0 (Const_0): HIB_IO_1 pin selected 1 (Const_1): HIB_IO_0 pin selected |
GPI0SEL | General Purpose Input 0 Selection 0 (Const_0): #0 1 (Const_1): HIB_IO_0 pin selected |
HIBIO0POL | HIBIO0 Polarity Set 0 (Const_0): Direct value 1 (Const_1): Inverted value |
HIBIO1POL | HIBIO1 Polarity Set 0 (Const_0): Direct value 1 (Const_1): Inverted value |
HIBIO0SEL | HIB_IO_0 Pin I/O Control (default HIBOUT) 0 (Const_0000): Direct input, No input pull device connected 1 (Const_0001): Direct input, Input pull-down device connected 2 (Const_0010): Direct input, Input pull-up device connected 8 (Const_1000): Push-pull HIB Control output 9 (Const_1001): Push-pull WDT service output 10 (Const_1010): Push-pull GPIO output 12 (Const_1100): Open-drain HIB Control output 13 (Const_1101): Open-drain WDT service output 14 (Const_1110): Open-drain GPIO output 15 (Const_1111): #1111 |
HIBIO1SEL | HIB_IO_1 Pin I/O Control (Default WKUP) 0 (Const_0000): Direct input, No input pull device connected 1 (Const_0001): Direct input, Input pull-down device connected 2 (Const_0010): Direct input, Input pull-up device connected 8 (Const_1000): Push-pull HIB Control output 9 (Const_1001): Push-pull WDT service output 10 (Const_1010): Push-pull GPIO output 12 (Const_1100): Open-drain HIB Control output 13 (Const_1101): Open-drain WDT service output 14 (Const_1110): Open-drain GPIO output 15 (Const_1111): #1111 |