PLL Configuration 0 Register
VCOBYP | VCO Bypass 0 (Const_0): Normal operation, VCO is not bypassed 1 (Const_1): Prescaler Mode, VCO is bypassed |
VCOPWD | VCO Power Saving Mode 0 (Const_0): Normal behavior 1 (Const_1): The VCO is put into a Power Saving Mode and can no longer be used. Only the Bypass and Prescaler Mode are active if previously selected. |
VCOTR | VCO Trim Control 0 (Const_0): VCO bandwidth is operation in the normal range. VCO output frequency is between 260 and 520 MHz for a input frequency between 8 and 16 MHz. 1 (Const_1): VCO bandwidth is operation in the test range. VCO output frequency is between 260 and 520 MHz for a input frequency between 8 and 16 MHz. |
FINDIS | Disconnect Oscillator from VCO 0 (Const_0): connect oscillator to the VCO part 1 (Const_1): disconnect oscillator from the VCO part. |
OSCDISCDIS | Oscillator Disconnect Disable 0 (Const_0): In case of a PLL loss-of-lock bit FINDIS is set 1 (Const_1): In case of a PLL loss-of-lock bit FINDIS is cleared |
PLLPWD | PLL Power Saving Mode 0 (Const_0): Normal behavior 1 (Const_1): The complete PLL block is put into a Power Saving Mode and can no longer be used. Only the Bypass Mode is active if previously selected. |
OSCRES | Oscillator Watchdog Reset 0 (Const_0): The Oscillator Watchdog of the PLL is not reset and remains active 1 (Const_1): The Oscillator Watchdog of the PLL is reset |
RESLD | Restart VCO Lock Detection |
AOTREN | Automatic Oscillator Calibration Enable 0 (Const_0): Disable 1 (Const_1): Enable |
FOTR | Factory Oscillator Calibration 0 (Const_0): No effect 1 (Const_1): Force fixed-value trimming |