EBUDIV=value1, DISS=value1, SYNCACK=value1, SYNC=value1, DISR=value1, EBUDIVACK=value1, DIV2ACK=value1, DIV2=value1
EBU Clock Control Register
DISR | EBU Disable Request Bit 0 (value1): EBU disable is not requested 1 (value2): EBU disable is requested |
DISS | EBU Disable Status Bit 0 (value1): EBU is enabled (default after reset) 1 (value2): EBU is disabled |
SYNC | EBU Clocking Mode 0 (value1): request EBU to run asynchronously to AHB bus clock and use separate clock source 1 (value2): request EBU to run synchronously to ARM processor (default after reset) |
DIV2 | DIV2 Clocking Mode 0 (value1): standard clocking mode. clock input selected by SYNC bitfield (default after reset). 1 (value2): request EBU to run off AHB bus clock divided by 2. |
EBUDIV | EBU Clock Divide Ratio 0 (value1): request EBU to run off input clock (default after reset) 1 (value2): request EBU to run off input clock divided by 2 2 (value3): request EBU to run off input clock divided by 3 3 (value4): request EBU to run off input clock divided by 4 |
SYNCACK | EBU Clocking Mode Status 0 (value1): the EBU is asynchronous to the AHB bus clock and is using a separate clock source 1 (value2): EBU is synchronous to the AHB bus clock (default after reset) |
DIV2ACK | DIV2 Clocking Mode Status 0 (value1): EBU is using standard clocking mode. clock input selected by SYNC bitfield (default after reset). 1 (value2): EBU is running off AHB bus clock divided by 2. |
EBUDIVACK | EBU Clock Divide Ratio Status 0 (value1): EBU is running off input clock (default after reset) 1 (value2): EBU is running off input clock divided by 2 2 (value3): EBU is running off input clock divided by 3 3 (value4): EBU is running off input clock divided by 4 |