Infineon /XMC4700 /EBU /MODCON

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MODCON

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (STS)STS 0 (LCKABRT)LCKABRT 0 (value1)SDTRI 0 (value1)EXTLOCK 0 (value1)ARBSYNC 0 (value1)ARBMODE 0 (value1)TIMEOUTC0LOCKTIMEOUT0GLOBALCS 0 (ACCSINH)ACCSINH 0 (ACCSINHACK)ACCSINHACK 0 (value1)ALE

ARBSYNC=value1, SDTRI=value1, ALE=value1, TIMEOUTC=value1, ARBMODE=value1, EXTLOCK=value1

Description

EBU Configuration Register

Fields

STS

Memory Status Bit

LCKABRT

Lock Abort

SDTRI

SDRAM Tristate

0 (value1): SDRAM control signals are driven by the EBU when the EBU does not own the external bus. SDRAM cannot be shared.

1 (value2): SDRAM control signals are tri-stated by the EBU when the EBU does not own the external bus. The SDRAM can be shared.

EXTLOCK

External Bus Lock Control

0 (value1): External bus is not locked after the EBU gains ownership

1 (value2): External bus is locked after the EBU gains ownership

ARBSYNC

Arbitration Signal Synchronization Control

0 (value1): Arbitration inputs are synchronous

1 (value2): Arbitration inputs are asynchronous

ARBMODE

Arbitration Mode Selection

0 (value1): No Bus arbitration mode selected

1 (value2): Arbiter Mode arbitration mode selected

2 (value3): Participant arbitration mode selected

3 (value4): Sole Master arbitration mode selected

TIMEOUTC

Bus Time-out Control

0 (value1): Time-out is disabled.

1 (value2): Time-out is generated after 1 8 clock cycles.

255 (value3): Time-out is generated after 255 8 clock cycles.

LOCKTIMEOUT

Lock Timeout Counter Preload

GLOBALCS

Global Chip Select Enable

ACCSINH

Access Inhibit request

ACCSINHACK

Access inhibit acknowledge

ALE

ALE Mode

0 (value1): Output is ADV

1 (value2): Output is ALE