CNT_LO_CH5=1, HYST_LO_CH4=HYSTOFF, HYST_LO_CH7=HYSTOFF, CNT_LO_CH6=1, CNT_LO_CH4=1, CNT_LO_CH7=1, HYST_LO_CH6=HYSTOFF, HYST_LO_CH5=HYSTOFF
Lower counter trigger level channel 4-7 register
CNT_LO_CH4 | Lower timer trigger threshold channel 4 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_LO_CH4 | Channel 4 lower hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_LO_CH5 | Lower timer trigger threshold channel 5 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_LO_CH5 | Channel 5 lower hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_LO_CH6 | Lower timer trigger threshold channel 6 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_LO_CH6 | Channel 6 lower hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_LO_CH7 | Lower timer trigger threshold channel 7 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_LO_CH7 | Channel 7 lower hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |