CNT_UP_CH8=1, HYST_UP_CH11=HYSTOFF, CNT_UP_CH11=1, CNT_UP_CH10=1, HYST_UP_CH8=HYSTOFF, HYST_UP_CH10=HYSTOFF, HYST_UP_CH9=HYSTOFF, CNT_UP_CH9=1
Upper counter trigger level channel 8-11 register
CNT_UP_CH8 | Upper timer trigger threshold channel 8 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH8 | Channel 8 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_CH9 | Upper timer trigger threshold channel 9 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH9 | Channel 9 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_CH10 | Upper timer trigger threshold channel 10 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH10 | Channel 10 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_CH11 | Upper timer trigger threshold channel 11 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (16): 16 measurements 5 (32): 32 measurements 6 (63): 63 measurements 7 (63): 63 measurements |
HYST_UP_CH11 | Channel 11 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |