HYST_UP_DCH2=HYSTOFF, HYST_UP_DCH4=HYSTOFF, CNT_UP_DCH3=1, CNT_UP_DCH2=1, HYST_UP_DCH1=HYSTOFF, CNT_UP_DCH4=1, CNT_UP_DCH1=1, HYST_UP_DCH3=HYSTOFF
Upper counter trigger level differential channel 1-4 register
CNT_UP_DCH1 | Upper timer trigger threshold differential channel 1 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (15): 15 measurements 5 (15): 15 measurements 6 (15): 15 measurements 7 (15): 15 measurements |
HYST_UP_DCH1 | Differential channel 1 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_DCH2 | Upper timer trigger threshold differential channel 2 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (15): 15 measurements 5 (15): 15 measurements 6 (15): 15 measurements 7 (15): 15 measurements |
HYST_UP_DCH2 | Differential channel 2 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_DCH3 | Upper timer trigger threshold differential channel 3 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (15): 15 measurements 5 (15): 15 measurements 6 (15): 15 measurements 7 (15): 15 measurements |
HYST_UP_DCH3 | Differential channel 3 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |
CNT_UP_DCH4 | Upper timer trigger threshold differential channel 4 0 (1): 1 measurement 1 (2): 2 measurements 2 (4): 4 measurements 3 (8): 8 measurements 4 (15): 15 measurements 5 (15): 15 measurements 6 (15): 15 measurements 7 (15): 15 measurements |
HYST_UP_DCH4 | Differential channel 4 upper hysteresis 0 (HYSTOFF): Hysteresis switched off 1 (HYST4): Hysteresis = 4 2 (HYST8): Hysteresis = 8 3 (HYST16): Hysteresis = 16 |