Infineon /tle984x /ADC1 /FILT_OUT0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FILT_OUT0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0FILT_OUT_CH00 (DISABLE)WFR0 0 (NOT_VALID)VF0 0 (NO_OVERRUN)OF0

OF0=NO_OVERRUN, WFR0=DISABLE, VF0=NOT_VALID

Description

ADC1 or filter output channel 0 register

Fields

FILT_OUT_CH0

ADC or filter output value channel 0

WFR0

Wait for read mode

0 (DISABLE): Overwrite mode

1 (ENABLE): Wait for read mode enabled

VF0

Valid flag

0 (NOT_VALID): No new valid data available

1 (VALID): Result register contains valid data and has not yet been read

OF0

Overrun flag

0 (NO_OVERRUN): Result register not overwritten

1 (OVERRUN): Result register overwritten

Links

() ()