Infineon /tle984x /ADC1 /FILT_OUT10

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FILT_OUT10

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0FILT_OUT_CH100 (DISABLE)WFR10 0 (NOT_VALID)VF10 0 (NO_OVERRUN)OF10

VF10=NOT_VALID, WFR10=DISABLE, OF10=NO_OVERRUN

Description

ADC1 or filter output channel 10 register

Fields

FILT_OUT_CH10

ADC or filter output value channel 10

WFR10

Wait for read mode

0 (DISABLE): Overwrite mode

1 (ENABLE): Wait for read mode enabled

VF10

Valid flag

0 (NOT_VALID): No new valid data available

1 (VALID): Result register contains valid data and has not yet been read

OF10

Overrun flag

0 (NO_OVERRUN): Result register not overwritten

1 (OVERRUN): Result register overwritten

Links

() ()