Infineon /tle984x /ADC1 /FILT_OUT12

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FILT_OUT12

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0FILT_OUT_CH120 (DISABLE)WFR12 0 (NOT_VALID)VF12 0 (NO_OVERRUN)OF12

OF12=NO_OVERRUN, VF12=NOT_VALID, WFR12=DISABLE

Description

ADC1 or filter output channel 12 register

Fields

FILT_OUT_CH12

ADC or filter output value channel 12

WFR12

Wait for read mode

0 (DISABLE): Overwrite mode

1 (ENABLE): Wait for read mode enabled

VF12

Valid flag

0 (NOT_VALID): No new valid data available

1 (VALID): Result register contains valid data and has not yet been read

OF12

Overrun flag

0 (NO_OVERRUN): Result register not overwritten

1 (OVERRUN): Result register overwritten

Links

() ()