Infineon /tle984x /ADC1 /FILT_OUTEIM

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FILT_OUTEIM

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0FILT_OUT_EIM0 (DISABLE)WFR_EIM 0 (NOT_VALID)VF_EIM 0 (NO_OVERRUN)OF_EIM

VF_EIM=NOT_VALID, WFR_EIM=DISABLE, OF_EIM=NO_OVERRUN

Description

ADC1 or filter output of EIM register

Fields

FILT_OUT_EIM

ADC or filter output value for last EIM measurement

WFR_EIM

Wait for read mode

0 (DISABLE): Overwrite mode

1 (ENABLE): Wait for read mode enabled

VF_EIM

Valid flag

0 (NOT_VALID): No new valid data available

1 (VALID): Result register contains valid data and has not yet been read

OF_EIM

Overrun flag

0 (NO_OVERRUN): Result register not overwritten

1 (OVERRUN): Result register overwritten