31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (INACTIVE)VS_LO_ISC 0 (INACTIVE)MON1_LO_ISC 0 (INACTIVE)MON2_LO_ISC 0 (INACTIVE)MON3_LO_ISC 0 (INACTIVE)MON4_LO_ISC 0 (INACTIVE)MON5_LO_ISC 0 (INACTIVE)P2_1_LO_ISC 0 (INACTIVE)P2_2_LO_ISC 0 (INACTIVE)P2_3_LO_ISC 0 (INACTIVE)P2_6_LO_ISC 0 (INACTIVE)P2_7_LO_ISC 0 (INACTIVE)VS_UP_ISC 0 (INACTIVE)MON1_UP_ISC 0 (INACTIVE)MON2_UP_ISC 0 (INACTIVE)MON3_UP_ISC 0 (INACTIVE)MON4_UP_ISC 0 (INACTIVE)MON5_UP_ISC 0 (INACTIVE)P2_1_UP_ISC 0 (INACTIVE)P2_2_UP_ISC 0 (INACTIVE)P2_3_UP_ISC 0 (INACTIVE)P2_6_UP_ISC 0 (INACTIVE)P2_7_UP_ISC

P2_1_UP_ISC=INACTIVE, MON4_UP_ISC=INACTIVE, P2_2_UP_ISC=INACTIVE, P2_7_LO_ISC=INACTIVE, P2_1_LO_ISC=INACTIVE, P2_6_LO_ISC=INACTIVE, MON5_LO_ISC=INACTIVE, VS_UP_ISC=INACTIVE, MON5_UP_ISC=INACTIVE, MON3_LO_ISC=INACTIVE, MON1_LO_ISC=INACTIVE, P2_7_UP_ISC=INACTIVE, VS_LO_ISC=INACTIVE, MON3_UP_ISC=INACTIVE, MON2_UP_ISC=INACTIVE, P2_3_LO_ISC=INACTIVE, MON4_LO_ISC=INACTIVE, MON2_LO_ISC=INACTIVE, P2_6_UP_ISC=INACTIVE, P2_2_LO_ISC=INACTIVE, MON1_UP_ISC=INACTIVE, P2_3_UP_ISC=INACTIVE

Description

ADC1 interrupt status clear 2 register

Fields

VS_LO_ISC

ADC1 VS lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON1_LO_ISC

ADC1 MON 1 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON2_LO_ISC

ADC1 MON 2 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON3_LO_ISC

ADC1 MON 3 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON4_LO_ISC

ADC1 MON 4 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON5_LO_ISC

ADC1 MON 5 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_1_LO_ISC

ADC1 port 2.1 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_2_LO_ISC

ADC1 port 2.2 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_3_LO_ISC

ADC1 port 2.3 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_6_LO_ISC

ADC1 port 2.6 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_7_LO_ISC

ADC1 port 2.7 lower threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

VS_UP_ISC

ADC1 VS upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON1_UP_ISC

ADC1 MON 1 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON2_UP_ISC

ADC1 MON 2 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON3_UP_ISC

ADC1 MON 3 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON4_UP_ISC

ADC1 MON 4 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

MON5_UP_ISC

ADC1 MON 5 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_1_UP_ISC

ADC1 port 2.1 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_2_UP_ISC

ADC1 port 2.2 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_3_UP_ISC

ADC1 port 2.3 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_6_UP_ISC

ADC1 port 2.6 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared

P2_7_UP_ISC

ADC1 port 2.7 upper threshold interrupt status clear

0 (INACTIVE): Interrupt status is not cleared

1 (ACTIVE): Interrupt status is cleared