MSEL_Ch4=MMODE0, MSEL_Ch6=MMODE0, MSEL_Ch7=MMODE0, MSEL_Ch5=MMODE0, MSEL_Ch2=MMODE0, MSEL_Ch1=MMODE0, MSEL_Ch3=MMODE0, MSEL_Ch0=MMODE0
Overvoltage measurement mode of channel 0-7 register
MSEL_Ch0 | Measurement mode ch 0 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch1 | Measurement mode ch 1 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch2 | Measurement mode ch 2 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch3 | Measurement mode ch 3 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch4 | Measurement mode ch 4 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch5 | Measurement mode ch 5 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch6 | Measurement mode ch 6 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |
MSEL_Ch7 | Measurement mode ch 7 0 (MMODE0): Upper & lower voltage/limit measurement 1 (MMODEUV): Undervoltage/-limit measurement 2 (MMODEOV): Overvoltage/-limit measurement |