Infineon /tle984x /CCU6 /T12DTC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as T12DTC

15 1211 87 43 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0DTM0 (DISABLED)DTE0 0 (DISABLED)DTE1 0 (DISABLED)DTE2 0 (Zero)DTR0 0 (Zero)DTR1 0 (Zero)DTR2

DTE2=DISABLED, DTE1=DISABLED, DTR2=Zero, DTE0=DISABLED, DTR1=Zero, DTR0=Zero

Description

Dead-time control register for timer T12 low register

Fields

DTM

Dead-time

DTE0

Dead-time enable bit 0

0 (DISABLED): Dead-time generation is disabled. The corresponding outputs switch from the passive state to the active state (according to the actual compare status) without any delay

1 (ENABLED): Dead-time generation is enabled. The corresponding outputs switch from the passive state to the active state (according to the compare status) with the delay programmed in bit field DTM

DTE1

Dead-time enable bit 1

0 (DISABLED): Dead-time generation is disabled. The corresponding outputs switch from the passive state to the active state (according to the actual compare status) without any delay

1 (ENABLED): Dead-time generation is enabled. The corresponding outputs switch from the passive state to the active state (according to the compare status) with the delay programmed in bit field DTM

DTE2

Dead-time enable bit 2

0 (DISABLED): Dead-time generation is disabled. The corresponding outputs switch from the passive state to the active state (according to the actual compare status) without any delay

1 (ENABLED): Dead-time generation is enabled. The corresponding outputs switch from the passive state to the active state (according to the compare status) with the delay programmed in bit field DTM

DTR0

Dead-time run indication bit 0

0 (Zero): The value of the corresponding dead-time counter channel is 0

1 (Not_zero): The value of the corresponding dead-time counter channel is not 0

DTR1

Dead-time run indication bit 1

0 (Zero): The value of the corresponding dead-time counter channel is 0

1 (Not_zero): The value of the corresponding dead-time counter channel is not 0

DTR2

Dead-time run indication bit 2

0 (Zero): The value of the corresponding dead-time counter channel is 0

1 (Not_zero): The value of the corresponding dead-time counter channel is not 0