DTE2=DISABLED, DTE1=DISABLED, DTR2=Zero, DTE0=DISABLED, DTR1=Zero, DTR0=Zero
Dead-time control register for timer T12 low register
DTM | Dead-time |
DTE0 | Dead-time enable bit 0 0 (DISABLED): Dead-time generation is disabled. The corresponding outputs switch from the passive state to the active state (according to the actual compare status) without any delay 1 (ENABLED): Dead-time generation is enabled. The corresponding outputs switch from the passive state to the active state (according to the compare status) with the delay programmed in bit field DTM |
DTE1 | Dead-time enable bit 1 0 (DISABLED): Dead-time generation is disabled. The corresponding outputs switch from the passive state to the active state (according to the actual compare status) without any delay 1 (ENABLED): Dead-time generation is enabled. The corresponding outputs switch from the passive state to the active state (according to the compare status) with the delay programmed in bit field DTM |
DTE2 | Dead-time enable bit 2 0 (DISABLED): Dead-time generation is disabled. The corresponding outputs switch from the passive state to the active state (according to the actual compare status) without any delay 1 (ENABLED): Dead-time generation is enabled. The corresponding outputs switch from the passive state to the active state (according to the compare status) with the delay programmed in bit field DTM |
DTR0 | Dead-time run indication bit 0 0 (Zero): The value of the corresponding dead-time counter channel is 0 1 (Not_zero): The value of the corresponding dead-time counter channel is not 0 |
DTR1 | Dead-time run indication bit 1 0 (Zero): The value of the corresponding dead-time counter channel is 0 1 (Not_zero): The value of the corresponding dead-time counter channel is not 0 |
DTR2 | Dead-time run indication bit 2 0 (Zero): The value of the corresponding dead-time counter channel is 0 1 (Not_zero): The value of the corresponding dead-time counter channel is not 0 |