Infineon /tle984x /HS /CTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLE)HS1_EN 0 (DISABLE)HS1_PWM 0 (OFF)HS1_ON 0 (DISABLE)HS1_OL_EN 0 (OFF)HS1_CYC_ON_ACTIVE 0 (SLEW_RATE_1)HS1_SRCTL_SEL 0 (IOCTH0)HS1_OC_SEL 0 (DISABLE)HS2_EN 0 (DISABLE)HS2_PWM 0 (OFF)HS2_ON 0 (DISABLE)HS2_OL_EN 0 (OFF)HS2_CYC_ON_ACTIVE 0 (SLEW_RATE_1)HS2_SRCTL_SEL 0 (IOCTH0)HS2_OC_SEL

HS1_EN=DISABLE, HS1_CYC_ON_ACTIVE=OFF, HS1_PWM=DISABLE, HS1_OC_SEL=IOCTH0, HS1_SRCTL_SEL=SLEW_RATE_1, HS2_OC_SEL=IOCTH0, HS2_SRCTL_SEL=SLEW_RATE_1, HS2_OL_EN=DISABLE, HS2_EN=DISABLE, HS1_OL_EN=DISABLE, HS2_ON=OFF, HS2_PWM=DISABLE, HS1_ON=OFF, HS2_CYC_ON_ACTIVE=OFF

Description

High-side driver control register

Fields

HS1_EN

High side 1 enable

0 (DISABLE): HS circuit power off

1 (ENABLE): HS circuit power on

HS1_PWM

High side 1 PWM enable

0 (DISABLE): Disables control by PWM input

1 (ENABLE): Enables control by PWM input

HS1_ON

High side 1 on

0 (OFF): HS driver off

1 (ON): HS driver on

HS1_OL_EN

High side 1 open load detection enable

0 (DISABLE): Disable open load detection

1 (ENABLE): Enable open load detection

HS1_CYC_ON_ACTIVE

High side 1 cyclic ON driver

0 (OFF): Cyclic ON driver OFF

1 (ON): Cyclic ON driver ON

HS1_SRCTL_SEL

High side 1 slew rate control select

0 (SLEW_RATE_1): Slew rate 10 V/us is enabled

1 (SLEW_RATE_2): Slew rate 30 V/us is enabled

HS1_OC_SEL

High side 1 overcurrent threshold selection

0 (IOCTH0): 25 mA min.

1 (IOCTH1): 50 mA min.

2 (IOCTH2): 100 mA min.

3 (IOCTH3): 150 mA min.

HS2_EN

High side 2 enable

0 (DISABLE): HS circuit power off

1 (ENABLE): HS circuit power on

HS2_PWM

High side 2 PWM enable

0 (DISABLE): Disables control by PWM input

1 (ENABLE): Enables control by PWM input

HS2_ON

High side 2 on

0 (OFF): HS driver off

1 (ON): HS driver on

HS2_OL_EN

High side 2 open load detection enable

0 (DISABLE): Disable open load detection

1 (ENABLE): Enable open load detection

HS2_CYC_ON_ACTIVE

High side 2 cyclic ON driver

0 (OFF): Cyclic ON driver OFF

1 (ON): Cyclic ON driver ON

HS2_SRCTL_SEL

High side 2 slew rate control select

0 (SLEW_RATE_1): Slew rate 10 V/us is enabled

1 (SLEW_RATE_2): Slew rate 30 V/us is enabled

HS2_OC_SEL

High side 2 overcurrent threshold selection

0 (IOCTH0): 25 mA min.

1 (IOCTH1): 50 mA min.

2 (IOCTH2): 100 mA min.

3 (IOCTH3): 150 mA min.

Links

() ()