Infineon /tle984x /HS /IRQS

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as IRQS

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NO_OVERTEMPERATURE)HS1_OT_IS 0 (NORMAL)HS1_OL_IS 0 (NO_OVERCURRENT)HS1_OC_IS 0 (NO_OVERTEMPERATURE)HS1_OT_STS 0 (NO_OPEN_LOAD)HS1_OL_STS 0 (NO_OVERTEMPERATURE)HS2_OT_IS 0 (NORMAL)HS2_OL_IS 0 (NO_OVERCURRENT)HS2_OC_IS 0 (NO_OVERTEMPERATURE)HS2_OT_STS 0 (NO_OPEN_LOAD)HS2_OL_STS

HS1_OT_IS=NO_OVERTEMPERATURE, HS2_OT_IS=NO_OVERTEMPERATURE, HS1_OL_IS=NORMAL, HS2_OT_STS=NO_OVERTEMPERATURE, HS2_OL_STS=NO_OPEN_LOAD, HS2_OC_IS=NO_OVERCURRENT, HS2_OL_IS=NORMAL, HS1_OL_STS=NO_OPEN_LOAD, HS1_OT_STS=NO_OVERTEMPERATURE, HS1_OC_IS=NO_OVERCURRENT

Description

High-side driver interrupt status register

Fields

HS1_OT_IS

High side 1 overtemperature interrupt status

0 (NO_OVERTEMPERATURE): No overtemperature occurred

1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status

HS1_OL_IS

High side 1 open load interrupt status

0 (NORMAL): Normal load

1 (OPEN_LOAD): Open load detected, write sets status

HS1_OC_IS

High side 1 overcurrent interrupt status

0 (NO_OVERCURRENT): No overcurrent condition occurred

1 (OVERCURRENT): Overcurrent occurred; switch is automatically shut down. Write sets status

HS1_OT_STS

High side 1 overtemperature status

0 (NO_OVERTEMPERATURE): No overtemperature occurred

1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status

HS1_OL_STS

High side 1 open load interrupt status

0 (NO_OPEN_LOAD): No open load condition occurred

1 (OPEN_LOAD): Open load occurred; switch is not automatically shut down. Write sets status

HS2_OT_IS

High side 2 overtemperature interrupt status

0 (NO_OVERTEMPERATURE): No overtemperature occurred

1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status

HS2_OL_IS

High side 2 open load interrupt status

0 (NORMAL): Normal load

1 (OPEN_LOAD): Open load detected, write sets status

HS2_OC_IS

High side 2 overcurrent interrupt status

0 (NO_OVERCURRENT): No overcurrent condition occurred

1 (OVERCURRENT): Overcurrent occurred; switch is automatically shut down. Write sets status

HS2_OT_STS

High side 2 overtemperature status

0 (NO_OVERTEMPERATURE): No overtemperature occurred

1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status

HS2_OL_STS

High side 2 open load interrupt status

0 (NO_OPEN_LOAD): No open load condition occurred

1 (OPEN_LOAD): Open load occurred; switch is not automatically shut down. Write sets status