Infineon /tle984x /LS /CTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLE)LS1_EN 0 (DISABLE)LS1_PWM 0 (OFF)LS1_ON 0 (DISABLE)LS1_OL_EN 0 (SLOW)LS1_SRCTL_SEL 0 (DISABLE)LS2_EN 0 (DISABLE)LS2_PWM 0 (OFF)LS2_ON 0 (DISABLE)LS2_OL_EN 0 (SLOW)LS2_SRCTL_SEL

LS1_ON=OFF, LS2_PWM=DISABLE, LS2_OL_EN=DISABLE, LS2_EN=DISABLE, LS1_SRCTL_SEL=SLOW, LS1_EN=DISABLE, LS1_OL_EN=DISABLE, LS2_SRCTL_SEL=SLOW, LS1_PWM=DISABLE, LS2_ON=OFF

Description

Low-side driver control register

Fields

LS1_EN

Low-side switch 1 enable

0 (DISABLE): Disables LS1

1 (ENABLE): Enables LS1

LS1_PWM

Low-side switch 1 PWM enable

0 (DISABLE): Normal mode controlled by LS1_ON

1 (ENABLE): Enables LS1 for PWM mode

LS1_ON

Low-side switch 1 on/off

0 (OFF): Switches LS1 off

1 (ON): Turns LS1 on

LS1_OL_EN

Open load detection enable

0 (DISABLE): Open load detection

1 (ENABLE): Open load detection

LS1_SRCTL_SEL

Low-side switch 1 slew rate selection

0 (SLOW): Slow slew rate is selected

1 (FAST): Fast slew rate is selected

LS2_EN

Low-side switch 2 enable

0 (DISABLE): Disables LS2

1 (ENABLE): Enables LS2

LS2_PWM

Low-side switch 2 PWM enable

0 (DISABLE): Normal mode controlled by LS2_ON

1 (ENABLE): Enables LS2 for PWM mode

LS2_ON

Low-Side switch 2 on/off

0 (OFF): Switches LS2 off

1 (ON): Turns LS2 on

LS2_OL_EN

Open load detection enable

0 (DISABLE): Open load detection

1 (ENABLE): Open load detection

LS2_SRCTL_SEL

Low-side switch 2 slew rate selection

0 (SLOW): Slow slew rate is selected

1 (FAST): Fast slew rate is selected

Links

() ()