LS1_OT_PREWARN_STS=NO_OVERTEMPERATURE_PREWARN, LS2_OT_PREWARN_STS=NO_OVERTEMPERATURE_PREWARN, LS1_OT_STS=NO_OVERTEMPERATURE, LS2_OT_STS=NO_OVERTEMPERATURE, LS2_OC_IS=NO_OVERCURRENT, LS2_OL_IS=NO_OPEN_LOAD, LS2_OT_PREWARN_IS=NO_OVERTEMPERATURE_PREWARN, LS1_OC_IS=NO_OVERCURRENT, LS2_OT_IS=NO_OVERTEMPERATURE, LS1_OL_IS=NO_OPEN_LOAD, LS2_OL_STS=NO_OPEN_LOAD, LS1_OT_IS=NO_OVERTEMPERATURE, LS1_OT_PREWARN_IS=NO_OVERTEMPERATURE_PREWARN, LS1_OL_STS=NO_OPEN_LOAD
Low-side driver interrupt status register
LS1_OT_PREWARN_IS | Low-Side 1 overtemperature prewarning interrupt status 0 (NO_OVERTEMPERATURE_PREWARN): No overtemperature prewarn occurred. 1 (OVERTEMPERATURE_PREWARN): Overtemperature prewarn occurred. Write sets status |
LS1_OT_IS | Low-Side 1 overtemperature interrupt status 0 (NO_OVERTEMPERATURE): No overtemperature occurred 1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status |
LS1_OL_IS | Low-Side 1 open load interrupt status 0 (NO_OPEN_LOAD): No open load condition occurred 1 (OPEN_LOAD): Open load occurred; switch is not automatically shut down. Write sets status |
LS1_OC_IS | Low-Side 1 overcurrent interrupt status 0 (NO_OVERCURRENT): No overcurrent condition occurred 1 (OVERCURRENT): Overcurrent occurred; switch is automatically shut down. Write sets status |
LS1_OT_PREWARN_STS | Low-Side 1 overtemperature prewarning status 0 (NO_OVERTEMPERATURE_PREWARN): No overtemperature prewarn occurred 1 (OVERTEMPERATURE): Overtemperature prewarn occurred; Write sets status |
LS1_OT_STS | Low-Side 1 overtemperature status 0 (NO_OVERTEMPERATURE): No overtemperature occurred 1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status |
LS1_OL_STS | Low-Side 1 open load status 0 (NO_OPEN_LOAD): No open load condition occurred 1 (OPEN_LOAD): Open load occurred; switch is not automatically shut down. Write sets status |
LS2_OT_PREWARN_IS | Low-Side 2 overtemperature prewarning interrupt status 0 (NO_OVERTEMPERATURE_PREWARN): No overtemperature prewarn occurred 1 (OVERTEMPERATURE_PREWARN): Overtemperature prewarn occurred. Write sets status |
LS2_OT_IS | Low-Side 2 overtemperature interrupt status 0 (NO_OVERTEMPERATURE): No overtemperature occurred 1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status |
LS2_OL_IS | Low-Side 2 open load interrupt status 0 (NO_OPEN_LOAD): No open load condition occurred 1 (OPEN_LOAD): Open load occurred; switch is not automatically shut down. Write sets status |
LS2_OC_IS | Low-Side 2 overcurrent interrupt status 0 (NO_OVERCURRENT): No overcurrent condition occurred 1 (OVERCURRENT): Overcurrent occurred; switch is automatically shut down. Write sets status |
LS2_OT_PREWARN_STS | Low-Side 2 overtemperature prewarning status 0 (NO_OVERTEMPERATURE_PREWARN): No overtemperature prewarn occurred 1 (OVERTEMPERATURE_PREWARN): Overtemperature prewarn occurred. Write sets status |
LS2_OT_STS | Low-Side 2 overtemperature status 0 (NO_OVERTEMPERATURE): No overtemperature occurred 1 (OVERTEMPERATURE): Overtemperature occurred; switch is automatically shut down. Write sets status |
LS2_OL_STS | Low-side 2 open load status 0 (NO_OPEN_LOAD): No open load condition occurred 1 (OPEN_LOAD): Open load occurred; switch is not automatically shut down. Write sets status |