Infineon /tle984x /MF /TEMPSENSE_CTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as TEMPSENSE_CTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (INACTIVE)LS_OTWARN_STS 0 (INACTIVE)LS_OT_STS 0 (INACTIVE)SYS_OTWARN_STS 0 (INACTIVE)SYS_OT_STS

SYS_OTWARN_STS=INACTIVE, LS_OT_STS=INACTIVE, SYS_OT_STS=INACTIVE, LS_OTWARN_STS=INACTIVE

Description

Temperature sensor control register

Fields

LS_OTWARN_STS

Low-side overtemperature warning (MU) status

0 (INACTIVE): Write clears status

1 (ACTIVE): Interrupt status set

LS_OT_STS

Low-side overtemperature (MU) status

0 (INACTIVE): Write clears status

1 (ACTIVE): Interrupt status set

SYS_OTWARN_STS

System overtemperature warning (MU) status

0 (INACTIVE): Write clears status

1 (ACTIVE): Interrupt status set

SYS_OT_STS

System overtemperature (MU) status

0 (INACTIVE): Write clears status

1 (ACTIVE): Interrupt status set