Infineon /tle984x /PMU /VDDEXT_CTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as VDDEXT_CTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLE)VDDEXT_ENABLE 0 (DISABLE)VDDEXT_CYC_EN 0 (DISABLE)VDDEXT_FAIL_EN 0 (No_overtemperature)VDDEXT_OT_IS 0 (Not_in_undervoltage)VDDEXT_UV_IS 0 (No_overtemperature)VDDEXT_OT_STS 0 (No_overtemperature)VDDEXT_OT 0 (Not_stable)VDDEXT_STABLE 0 (Not_cleared)VDDEXT_OT_ISC 0 (Not_cleared)VDDEXT_UV_ISC 0 (Status_not_cleared)VDDEXT_OT_SC

VDDEXT_ENABLE=DISABLE, VDDEXT_STABLE=Not_stable, VDDEXT_OT_STS=No_overtemperature, VDDEXT_CYC_EN=DISABLE, VDDEXT_OT_SC=Status_not_cleared, VDDEXT_UV_IS=Not_in_undervoltage, VDDEXT_OT=No_overtemperature, VDDEXT_OT_ISC=Not_cleared, VDDEXT_UV_ISC=Not_cleared, VDDEXT_FAIL_EN=DISABLE, VDDEXT_OT_IS=No_overtemperature

Description

VDDEXT control register

Fields

VDDEXT_ENABLE

VDDEXT supply enable

0 (DISABLE): VDDEXT supply disabled

1 (ENABLE): VDDEXT supply enabled

VDDEXT_CYC_EN

VDDEXT supply for cyclic sense enable

0 (DISABLE): VDDEXT for cyclic sense disable

1 (ENABLE): VDDEXT for cyclic sense enable

VDDEXT_FAIL_EN

Enabling of VDDEXT supply status information as interrupt source

0 (DISABLE): VDDEXT fail interrupts are disabled

1 (ENABLE): VDDEXT fail Interrupts are enabled

VDDEXT_OT_IS

VDDEXT supply overtemperature interrupt status

0 (No_overtemperature): VDDEXT no overtemperature condition

1 (Overtemperature): VDDEXT overtemperature condition

VDDEXT_UV_IS

VDDEXT supply undervoltage interrupt status

0 (Not_in_undervoltage): VDDEXT not in undervoltage condition

1 (In_undervoltage): VDDEXT in undervoltage condition

VDDEXT_OT_STS

VDDEXT supply overtemperature status

0 (No_overtemperature): VDDEXT not in overtemperature condition

1 (Overtemperature): VDDEXT in overtemperature condition

VDDEXT_OT

VDDEXT supply overtemperature

0 (No_overtemperature): VDDEXT not in overtemperature condition

1 (Overtemperature): VDDEXT in overtemperature condition

VDDEXT_STABLE

VDDEXT supply stable

0 (Not_stable): VDDEXT not in stable condition

1 (Stable): VDDEXT in stable condition

VDDEXT_OT_ISC

VDDEXT supply overtemperature interrupt status clear

0 (Not_cleared): VDDEXTovertemperature not cleared

1 (Cleared): VDDEXTovertemperature cleared

VDDEXT_UV_ISC

VDDEXT supply undervoltage interrupt status clear

0 (Not_cleared): VDDEXT undervoltage not cleared

1 (Cleared): VDDEXT undervoltage cleared

VDDEXT_OT_SC

VDDEXT supply overtemperature status clear

0 (Status_not_cleared): VDDEXT overtemperature status not cleared

1 (Status_cleared): VDDEXT overtemperature status cleared