WDT1_SEQ_FAIL=No_fail, SYS_OT=NORMAL, LP_CLKWD=NORMAL, PMU_1V5_OVL=No_overload, PMU_5V_OVL=No_overload, SUPP_SHORT=Main_supply_ok
WFS system fail register
SUPP_SHORT | Supply short 0 (Main_supply_ok): VDDP or VDDC are in expected range 1 (Main_supply_short): VDDP or VDDC do not have stable operating point |
PMU_1V5_OVL | VDDC overload flag 0 (No_overload): VDDC ok 1 (Overload): Hall VDDC overload |
PMU_5V_OVL | VDDP overload flag 0 (No_overload): VDDP ok 1 (Overload): VDDP overload |
SYS_OT | System overtemperature indication flag 0 (NORMAL): Normal operation 1 (OT): Overtemperature |
WDT1_SEQ_FAIL | External watchdog (WDT1) sequential fail 0 (No_fail): No fail, system working properly 1 (Sequential_watchdog_fail): 5 consecutive watchdog fails |