Infineon /tle984x /SCU /GPT12ICLR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as GPT12ICLR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NOT_CLEARED)GPT1T2C 0 (NOT_CLEARED)GPT1T3C 0 (NOT_CLEARED)GPT1T4C 0 (NOT_CLEARED)GPT2T5C 0 (NOT_CLEARED)GPT2T6C 0 (NOT_CLEARED)GPT12CRC

GPT1T3C=NOT_CLEARED, GPT1T2C=NOT_CLEARED, GPT2T5C=NOT_CLEARED, GPT2T6C=NOT_CLEARED, GPT1T4C=NOT_CLEARED, GPT12CRC=NOT_CLEARED

Description

Timer and counter control/status clear register

Fields

GPT1T2C

GPT module 1 Timer2 interrupt status

0 (NOT_CLEARED): Interrupt event is not cleared

1 (CLEARED): Interrupt event is cleared

GPT1T3C

GPT module 1 Timer3 interrupt status

0 (NOT_CLEARED): Interrupt event is not cleared

1 (CLEARED): Interrupt event is cleared

GPT1T4C

GPT module 1 Timer4 interrupt status

0 (NOT_CLEARED): Interrupt event is not cleared

1 (CLEARED): Interrupt event is cleared

GPT2T5C

GPT module 2 Timer5 interrupt status

0 (NOT_CLEARED): Interrupt event is not cleared

1 (CLEARED): Interrupt event is cleared

GPT2T6C

GPT module 2 Timer6 interrupt status

0 (NOT_CLEARED): Interrupt event is not cleared

1 (CLEARED): Interrupt event is cleared

GPT12CRC

GPT12 capture reload interrupt status

0 (NOT_CLEARED): Interrupt event is not cleared

1 (CLEARED): Interrupt event is cleared

Links

() ()