Infineon /tle984x /SCUPM /SYS_ISCLR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as SYS_ISCLR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NO_CLEAR)SYS_OTWARN_ISC 0 (NO_CLEAR)SYS_OT_ISC 0 (NO_CLEAR)REFBG_LOTHWARN_ISC 0 (NO_CLEAR)REFBG_UPTHWARN_ISC 0 (NO_CLEAR)SYS_OTWARN_SC 0 (NO_CLEAR)SYS_OT_SC

REFBG_UPTHWARN_ISC=NO_CLEAR, REFBG_LOTHWARN_ISC=NO_CLEAR, SYS_OTWARN_SC=NO_CLEAR, SYS_OT_SC=NO_CLEAR, SYS_OT_ISC=NO_CLEAR, SYS_OTWARN_ISC=NO_CLEAR

Description

System interrupt status clear register

Fields

SYS_OTWARN_ISC

System overtemperature pre-warning status clear

0 (NO_CLEAR): The interrupt status is not cleared

1 (CLEAR): The interrupt status is cleared

SYS_OT_ISC

System overtemperature shutdown status clear

0 (NO_CLEAR): The interrupt status is not cleared

1 (CLEAR): The interrupt status is cleared

REFBG_LOTHWARN_ISC

8-bit ADC2 reference undervoltage interrupt status clear

0 (NO_CLEAR): The interrupt status is not cleared

1 (CLEAR): The interrupt status is cleared

REFBG_UPTHWARN_ISC

8-bit ADC2 reference overvoltage interrupt status clear

0 (NO_CLEAR): The interrupt status is not cleared

1 (CLEAR): The interrupt status is cleared

SYS_OTWARN_SC

System overtemperature pre-warning status clear

0 (NO_CLEAR): The interrupt status is not cleared

1 (CLEAR): The interrupt status is cleared

SYS_OT_SC

System overtemperature shutdown status clear

0 (NO_CLEAR): The interrupt status is not cleared

1 (CLEAR): The interrupt status is cleared