Infineon /tle984x /TRX /CTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (SLEEP)MODE 0 (ERROR)MODE_FB 0 (DOMINANT_STATE)TXD 0 (RXD)RXD 0 (NORMAL)SM0 (DISABLED)FB_SM0 (DISABLED)HV_MODE

SM=NORMAL, MODE_FB=ERROR, MODE=SLEEP, FB_SM=DISABLED, TXD=DOMINANT_STATE, HV_MODE=DISABLED

Description

Transceiver control register

Fields

MODE

Transceiver power mode control

0 (SLEEP): Tranceiver module switched to Sleep mode

1 (RECEIVE_ONLY): Tranceiver module switched to Receive-Only mode

3 (NORMAL): Tranceiver module switched to Normal mode

MODE_FB

Transmitter feedback signals settings [2:1]

0 (ERROR): Mode error

1 (SLEEP): Transceiver Sleep mode

2 (ERROR): Mode error

3 (ERROR): Mode error

4 (ERROR): Mode error

5 (RECEIVE_ONLY): Transceiver Receive-Only mode

6 (ERROR): Mode error

7 (NORMAL): Transceiver Normal mode

TXD

Transmitter state (only used when HV_MODE is set)

0 (DOMINANT_STATE): Transmitter switched on

1 (RECESSIVE_STATE): Transmitter switched off

RXD

Reveiver output signal

SM

Transmitter slope mode control

0 (NORMAL): Normal slope mode

1 (FAST): Fast slope mode

2 (LOW): Low slope mode

3 (FLASH): Flash mode

FB_SM

Feedback signal for slope mode setting [3:1]

0 (DISABLED): Transceiver module not enabled

1 (LOW): Low slope mode

2 (NORMAL): Normal slope mode

3 (FAST): Fast slope mode

4 (FLASH): Flash mode

5 (ERROR): Slope mode error

6 (ERROR): Slope mode error

7 (ERROR): Slope mode error

HV_MODE

Transceiver high-voltage I/O mode

0 (DISABLED): High-voltage mode entry disabled

1 (ENABLED): High-voltage mode entry enabled

Links

() ()