RDY=Busy
Data. The content of this register is valid only when RNG_IS = 1. When TRNG is disabled, read returns 0x0000 0000.
RDY | 32-bit random data is ready to read from TRNG_DATA register. Reading TRNG_DATA when RND_RDY=0 will return all 0’s. IRQ is generated when RND_RDY=1 if TRNG_CN.RND_IRQ_EN=1. 0 (Busy): TRNG Busy 1 (Ready): 32 bit random data is ready |
OD_HEALTH | On-Demand health test status. |
HEALTH | Health test status. |
SRCFAIL | Entropy source has failed. |
OD_ROMON | On demand ring oscillator test status. |
OD_EE | On demand entropy estimator status. |
PP_ERR | Post process error. |
ROMON_0_ERR | Ring Oscillator 0 Monitor Error. |
ROMON_1_ERR | Ring Oscillator 1 Monitor Error. |
ROMON_2_ERR | Ring Oscillator 2 Monitor Error. |
EE_ERR_THR | Entropy Estimator Threshold Error. |
EE_ERR_OOB | Entropy Estimator Out of Bounds Error… |
EE_ERR_LOCK | Entropy Estimator Lock Error. |
TERO_CNT_RDY | TERO Count Ready. |
RC_ERR | Repetition Count Error. |
AP_ERR | Adaptive Proportion Error. |
DATA_DONE | Data register has been loaded with at least 32 new entropy bits. |
DATA_NIST_DONE | Data NIST register has been loaded with at least 32 new entropy bits. |
HEALTH_DONE | Health Test Done. |
ROMON_DONE | Ring Oscillator Monitor Test Done. |
EE_DONE | Entropy Estimator Test Done. |