Interpret as BODCR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (BOD_EN)BOD_EN 0BOD_VL 0 (BOD_RSTEN)BOD_RSTEN 0 (BOD_INTF)BOD_INTF 0 (BOD_LPM)BOD_LPM 0 (BOD_OUT)BOD_OUT 0 (LVR_EN)LVR_EN

Description

Brown Out Detector Control Register

Fields

BOD_EN

Brown Out Detector Enable (initiated & write-protected bit) The default value is set by flash controller user configuration register config0 bit[23] 1= Brown Out Detector function is enabled 0= Brown Out Detector function is disabled

BOD_VL

Brown Out Detector Threshold Voltage Selection (initiated & write-protected bit) The default value is set by flash controller user configuration register config0 bit[22:21] BOV_VL[1] BOV_VL[0] Brown out voltage 1 1 4.5V 1 0 3.8V 0 1 2.7V 0 0 2.2V

BOD_RSTEN

Brown Out Reset Enable (initiated & write-protected bit) 1= Enable the Brown Out “RESET” function, when the Brown Out Detector function is enable and the detected voltage is lower than the threshold then assert a signal to reset the chip The default value is set by flash controller user configuration register config0 bit[20] 0= Enable the Brown Out “INTERRUPT” function, when the Brown Out Detector function is enable and the detected voltage is lower than the threshold then assert a signal to interrupt the MCU Cortex-M0 When the BOD_EN is enabled and the interrupt is assert, the interrupt will keep till to the BOD_EN set to “0”. The interrupt for CPU can be blocked by disable the NVIC in CPU for BOD interrupt or disable the interrupt source by disable the BOD_EN and then re-enable the BOD_EN function if the BOD function is required

BOD_INTF

Brown Out Detector Interrupt Flag 1= When Brown Out Detector detects the VDD is dropped through the voltage of BOD_VL setting or the VDD is raised up through the voltage of BOD_VL setting, this bit is set to “1” and the brown out interrupt is requested if brown out interrupt is enabled. 0= Brown Out Detector does not detect any voltage draft at VDD down through or up through the voltage of BOD_VL setting.

BOD_LPM

Brown Out Detector Low power Mode (write-protected bit) 1= Enable the BOD low power mode 0= BOD operate in normal mode (default) The BOD consumes about 100uA in normal mode, the low power mode can reduce the current to about 1/10 but slow the BOD response.

BOD_OUT

The status for Brown Out Detector output state 1= Brown Out Detector status output is 1, the detected voltage is lower than BOD_VL setting. If the BOD_EN is “0”(disabled), this bit always response “0” 0= Brown Out Detector status output is 0, the detected voltage is higher than BOD_VL setting

LVR_EN

Low Voltage Reset Enable (write-protected bit) The LVR function reset the chip when the input power voltage is lower than LVR circuit setting. LVR function is enabled in default. 1= Enabled Low Voltage Reset function - After enable the bit, the LVR function will active with 100uS delay for LVR output stable.(default). 0= Disabled Low Voltage Reset function