Comparator1 Control Register
| EN | Comparator1 Enable 1 = Enable 0 = Disable Comparator1 output needs wait 10 us stable time after CMP1EN is set |
| IE | Comparator1 Interrupt Enable 1 = Enable Comparator1 interrupt function 0 = Disable Comparator1 interrupt function Interrupt is generated if CMP1IE bit is set to 1 after comparator1 conversion finished. |
| HYSEN | Comparator1 Hysterisis Enable 1 = Enable comparator1 Hysterisis function; the typical range is 20mV. 0 = Disable comparator1 Hysterisis function (Default). |
| CN1 | Comparator1 negative input select 1 = The internal comparator reference voltage (Vref=1.2V) is selected as the negative comparator input 0 = The comparator1 reference pin CPN1 is selected as the negative comparator input |