CF=B_0x0
FDCAN Tx buffer cancellation finished register
CF | Cancellation finished Each Tx buffer has its own CF bit. The bits are set when the corresponding TXBRP bit is cleared after a cancellation was requested via TXBCR. In case the corresponding TXBRP bit was not set at the point of cancellation, CF is set immediately. The bits are reset when a new transmission is requested by writing a 1 to the corresponding bit of register TXBAR. 0 (B_0x0): No transmit buffer cancellation 1 (B_0x1): Transmit buffer cancellation finished |