STMicroelectronics /STM32U031 /PWR /PWR_SR1

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as PWR_SR1

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (WUF1)WUF1 0 (WUF2)WUF2 0 (WUF3)WUF3 0 (WUF4)WUF4 0 (WUF5)WUF5 0 (WUF7)WUF7 0 (B_0x0)SBF 0 (B_0x0)STOPF0 (WUFI)WUFI

STOPF=B_0x0, SBF=B_0x0

Description

Power status register 1

Fields

WUF1

Wake-up flag 1 This bit is set when a wake-up event is detected on wake-up pin, WKUP1. It is cleared by writing 1 in the CWUF1 bit of the PWR_SCR register.

WUF2

Wake-up flag 2 This bit is set when a wake-up event is detected on wake-up pin, WKUP2. It is cleared by writing 1 in the CWUF2 bit of the PWR_SCR register.

WUF3

Wake-up flag 3 This bit is set when a wake-up event is detected on wake-up pin, WKUP3. It is cleared by writing 1 in the CWUF3 bit of the PWR_SCR register.

WUF4

Wake-up flag 4 This bit is set when a wake-up event is detected on wake-up pin,WKUP4. It is cleared by writing 1 in the CWUF4 bit of the PWR_SCR register.

WUF5

Wake-up flag 5 This bit is set when a wake-up event is detected on wake-up pin, WKUP5. It is cleared by writing 1 in the CWUF5 bit of the PWR_SCR register.

WUF7

Wake-up flag 7 This bit is set when a wake-up event is detected on wake-up pin, WKUP7. It is cleared by writing 1 in the CWUF7 bit of the PWR_SCR register.

SBF

Standby flag This bit is set by hardware when the device enters the Standby mode and is cleared by setting the CSBF bit in the PWR_SCR register, or by a power-on reset. It is not cleared by the system reset.

0 (B_0x0): The device did not enter the Standby mode

1 (B_0x1): The device entered the Standby mode

STOPF

Stop Flags These bits are set by hardware when the device enters any stop mode and are cleared by setting the CSBF bit in the PWR_SCR register, or by a power-on reset. It is not cleared by the system reset.

0 (B_0x0): The device did not enter any Stop mode.

4 (B_0x4): The device entered in Stop 0 mode.

5 (B_0x5): The device entered in Stop 1 mode.

6 (B_0x6): The device entered in Stop 2 mode.

WUFI

Wake-up flag internal This bit is set when a wake-up is detected on the internal wake-up line. It is cleared when all internal wake-up sources are cleared.

Links

()