VOSRDY=B_0x0, ACTVOS=B_0x0, ACTVOSRDY=B_0x0
PWR voltage scaling status register
VOSRDY | Ready bit for Vless thansub>COREless than/sub> voltage scaling output selection. 0 (B_0x0): Not ready, voltage level below VOS selected level 1 (B_0x1): Ready, voltage level at or above VOS selected level |
ACTVOSRDY | Voltage level ready for currently used VOS 0 (B_0x0): Vless thansub>COREless than/sub> is above or below the current voltage scaling provided by ACTVOS[1:0] 1 (B_0x1): Vless thansub>COREless than/sub> is equal to the current voltage scaling provided by ACTVOS[1:0] |
ACTVOS | voltage output scaling currently applied to Vless thansub>COREless than/sub> 0 (B_0x0): VOS3 (lowest power) 1 (B_0x1): VOS2 2 (B_0x2): VOS1 3 (B_0x3): VOS0 (highest frequency) |