TRGO=B_0x0
ADF global control register
TRGO | Trigger output control This bit is set by software and reset by hardware. It is used to start the acquisition of several filters synchronously. It is also used to synchronize several ADF together by controlling the adf_trgo signal. 0 (B_0x0): Write 0 has no effect. Read 0 means that the trigger can be set again to 1. 1 (B_0x1): Write 1 generates a positive pulse on the adf_trgo signal and triggers the acquisition on enabled filter having their ACQMOD[2:0] = 01x and selecting TRGO as trigger. Read 1 means that the trigger pulse is still active. |