FRATE=B_0x0, CPTMODE=B_0x0, CPTREQ=B_0x0
DCMIPP Pipe0 flow control configuration register
FRATE | Frame capture rate control 0 (B_0x0): All frames are captured 1 (B_0x1): One out of two frames captured (50% bandwidth reduction) 2 (B_0x2): One out of four frames captured (75% bandwidth reduction) 3 (B_0x3): One out of eight frames captured (87% bandwidth reduction) |
CPTMODE | Capture mode 0 (B_0x0): Continuous grab mode - The received data are transferred into the destination memory through the AXI master. 1 (B_0x1): Snapshot mode (single frame) - Once activated, the interface waits for the start of frame, and then transfers a single frame through the AXI master. At the end of the frame, the CPTACT bit is automatically reset. |
CPTREQ | Capture requested 0 (B_0x0): Capture not requested for next frame 1 (B_0x1): Capture requested for next frame |