VCOREH=B_0x0, VCOREMONEN=B_0x0, VCOREL=B_0x0, VCORELLS=B_0x0
PWR control register 3
VCOREMONEN | V less than sub>DDCORE less than /sub> monitoring enable 0 (B_0x0): V less than sub>DDCORE less than /sub> monitoring disabled 1 (B_0x1): V less than sub>DDCORE less than /sub> monitoring enabled |
VCORELLS | V less than sub>DDCORE less than /sub> voltage detector low-level selection 0 (B_0x0): V less than sub>DDCORE less than /sub> low-voltage threshold 1 selected (VOS low) 1 (B_0x1): V less than sub>DDCORE less than /sub> low-voltage threshold 2 selected (VOS high) |
VCOREL | Monitored V less than sub>DDCORE less than /sub> level above low threshold 0 (B_0x0): V less than sub>DDCORE less than /sub> level above low threshold level, or monitor disabled 1 (B_0x1): V less than sub>DDCORE less than /sub> level equal or below low threshold level |
VCOREH | Monitored V less than sub>DDCORE less than /sub> level above high threshold 0 (B_0x0): V less than sub>DDCORE less than /sub> level below high threshold level, or monitor disabled 1 (B_0x1): V less than sub>DDCORE less than /sub> level equal or above high threshold level |