VCOREL=B_0x0, VCORELLS=B_0x0, VCOREH=B_0x0, VCOREMONEN=B_0x0
PWR control register 3
VCOREMONEN | Vless thansub>DDCOREless than/sub> monitoring enable 0 (B_0x0): Vless thansub>DDCOREless than/sub> monitoring disabled 1 (B_0x1): Vless thansub>DDCOREless than/sub> monitoring enabled |
VCORELLS | Vless thansub>DDCOREless than/sub> voltage detector low-level selection 0 (B_0x0): Vless thansub>DDCOREless than/sub> low-voltage threshold 1 selected (VOS low) 1 (B_0x1): Vless thansub>DDCOREless than/sub> low-voltage threshold 2 selected (VOS high) |
VCOREL | Monitored Vless thansub>DDCOREless than/sub> level above low threshold 0 (B_0x0): Vless thansub>DDCOREless than/sub> level above low threshold level, or monitor disabled 1 (B_0x1): Vless thansub>DDCOREless than/sub> level equal or below low threshold level |
VCOREH | Monitored Vless thansub>DDCOREless than/sub> level above high threshold 0 (B_0x0): Vless thansub>DDCOREless than/sub> level below high threshold level, or monitor disabled 1 (B_0x1): Vless thansub>DDCOREless than/sub> level equal or above high threshold level |