VDDIO5VMEN=B_0x0, VDDIO5VRSEL=B_0x0, VDDIO5RDY=B_0x0, VDDIO5VRSTBY=B_0x0, VDDIO5SV=B_0x0
PWR supply voltage monitoring control register 2
VDDIO5VMEN | Vless thansub>DDIO5 less than/sub>independent voltage monitor enable 0 (B_0x0): Vless thansub>DDIO5 less than/sub>voltage monitor disabled 1 (B_0x1): Vless thansub>DDIO5 less than/sub>voltage monitor enabled |
VDDIO5SV | Vless thansub>DDIO5 less than/sub>independent supply valid 0 (B_0x0): Vless thansub>DDIO5less than/sub> is not present. Logical and electrical isolation is applied to ignore this supply. 1 (B_0x1): Vless thansub>DDIO5less than/sub> is valid. |
VDDIO5RDY | Vless thansub>DDIO5 less than/sub>ready 0 (B_0x0): Vless thansub>DDIO5less than/sub> is below the threshold of the Vless thansub>DDIO5less than/sub> voltage monitor. 1 (B_0x1): Vless thansub>DDIO5less than/sub> is equal or above the threshold of the Vless thansub>DDIO5less than/sub> voltage monitor. |
VDDIO5VRSEL | Vless thansub>DDIO5less than/sub> I/O voltage range selection 0 (B_0x0): 3v3 voltage range selected. If Vless thansub>DDIO5less than/sub> is in 1v8 range with this setting, I/Os work in degraded mode. 1 (B_0x1): 1v8 voltage range selected. HSLV_VDDIO5 option bit must be set to allow 1v8 voltage range operation. Setting this configuration while Vless thansub>DDIO5less than/sub> is in 3v3 range damages the device. |
VDDIO5VRSTBY | Vless thansub>DDIO5less than/sub> I/O voltage range Standby mode 0 (B_0x0): VDDIO5VRSEL not retained in Standby mode 1 (B_0x1): VDDIO5VRSEL retained in Standby mod. |