IRQ_ENABLE register
EOC_IRQ | EOC_IRQ (Used in test mode only): set when the ADC conversion is completed. When read, provide the status of the interrupt: 0: ADC conversion is not completed 1: ADC conversion is completed Writing this bit clears the status of the interrupt: 0: no effect 1: clear the interrupt |
EODS_IRQ | EODS_IRQ: set when the Down Sampler conversion is completed. When read, provide the status of the interrupt: 0: Down Sampler conversion is not completed 1: Down Sampler conversion is completed Writing this bit clears the status of the interrupt: 0: no effect 1: clear the interrupt |
EOS_IRQ | EOS_IRQ: set when a sequence of conversion is completed. When read, provide the status of the interrupt: 0: sequence of conversion is not completed 1: sequence of conversion is completed Writing this bit clears the status of the interrupt: 0: no effect 1: clear the interrupt |
AWD_IRQ | AWD_IRQ: set when an analog watchdog event occurs. When read, provide the status of the interrupt: 0: no analog watchdog event occurred 1: analog watchdog event has occurred Writing this bit clears the status of the interrupt: 0: no effect 1: clear the interrupt |
OVR_DS_IRQ | OVR_DS_IRQ: set to indicate a Down Sampler overrun (at least one data is lost) When read, provide the status of the interrupt: 0: no overrun occurred 1: overrun occurred Writing this bit clears the status of the interrupt: 0: no effect 1: clear the interrupt |