EGR register
UG | UG: Update generation This bit can be set by software, it is automatically cleared by hardware. 0: No action. 1: Reinitialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected). |
CC1G | CC1G: Capture/Compare 1 generation This bit is set by software in order to generate an event, it is automatically cleared by hardware. 0: No action. 1: A capture/compare event is generated on channel 1: If channel CC1 is configured as output: CC1IF flag is set, Corresponding interrupt or DMA request is sent if enabled. If channel CC1 is configured as input: The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt or DMA request is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high. |
CC2G | CC2G: Capture/Compare 2 generation refer to CC1G description |
CC3G | CC3G: Capture/Compare 3 generation refer to CC1G description |
CC4G | CC4G: Capture/Compare 4 generation refer to CC1G description |
TG | TG: Trigger generation This bit is set by software in order to generate an event, it is automatically cleared by hardware. 0: No action 1: The TIF flag is set in TIMx_SR register. Related interrupt can occur if enabled. |