stm32 /stm32wb0 /STM32WB09 /ADC /SEQ_1

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as SEQ_1

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0SEQ00SEQ10SEQ20SEQ30SEQ40SEQ50SEQ60SEQ7

Description

SEQ_1 register

Fields

SEQ0

SEQ0[3:0]: channel number code for first conversion of the sequence

0000: VINM[0] to ADC single negative input

0001: VINM[1] to ADC single negative input

0010: VINM[2] to ADC single negative input

0011: VINM[3] to ADC single negative input

0100: VINP[0] to ADC single positive input

0101: VINP[1] to ADC single positive input

0110: VINP[2] to ADC single positive input

0111: VINP[3] to ADC single positive input

1000: VINP[0]-VINM[0] to ADC differential input

1001: VINP[1]-VINM[1] to ADC differential input

1010: VINP[2]-VINM[2] to ADC differential input

1011: VINP[3]-VINM[3] to ADC differential input

1100: VBAT Battery level detector

1101: Temperature sensor

111x: reserved

SEQ1

SEQ1[3:0]: channel number code for second conversion of the sequence.

See SEQ0 for code detail.

SEQ2

SEQ2[3:0]: channel number code for 3rd conversion of the sequence.

See SEQ0 for code detail.

SEQ3

SEQ3[3:0]: channel number code for 4th conversion of the sequence.

See SEQ0 for code detail.

SEQ4

SEQ4[3:0]: channel number code for 5th conversion of the sequence.

See SEQ0 for code detail.

SEQ5

SEQ5[3:0]: channel number code for 6th conversion of the sequence.

See SEQ0 for code detail.

SEQ6

SEQ6[3:0]: channel number code for 7th conversion of the sequence.

See SEQ0 for code detail.

SEQ7

SEQ7[3:0]: channel number code for 8th conversion of the sequence.

See SEQ0 for code detail.

Links

()