SEQ_1 register
SEQ0 | SEQ0[3:0]: channel number code for first conversion of the sequence 0000: VINM[0] to ADC single negative input 0001: VINM[1] to ADC single negative input 0010: VINM[2] to ADC single negative input 0011: VINM[3] to ADC single negative input 0100: VINP[0] to ADC single positive input 0101: VINP[1] to ADC single positive input 0110: VINP[2] to ADC single positive input 0111: VINP[3] to ADC single positive input 1000: VINP[0]-VINM[0] to ADC differential input 1001: VINP[1]-VINM[1] to ADC differential input 1010: VINP[2]-VINM[2] to ADC differential input 1011: VINP[3]-VINM[3] to ADC differential input 1100: VBAT Battery level detector 1101: Temperature sensor 111x: reserved |
SEQ1 | SEQ1[3:0]: channel number code for second conversion of the sequence. See SEQ0 for code detail. |
SEQ2 | SEQ2[3:0]: channel number code for 3rd conversion of the sequence. See SEQ0 for code detail. |
SEQ3 | SEQ3[3:0]: channel number code for 4th conversion of the sequence. See SEQ0 for code detail. |
SEQ4 | SEQ4[3:0]: channel number code for 5th conversion of the sequence. See SEQ0 for code detail. |
SEQ5 | SEQ5[3:0]: channel number code for 6th conversion of the sequence. See SEQ0 for code detail. |
SEQ6 | SEQ6[3:0]: channel number code for 7th conversion of the sequence. See SEQ0 for code detail. |
SEQ7 | SEQ7[3:0]: channel number code for 8th conversion of the sequence. See SEQ0 for code detail. |