COMP_SEL register
OFFSET_GAIN0 | OFFSET_GAIN0[1:0]: gain / offset used in ADC single negative mode with Vinput range = 1.2V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN1 | OFFSET_GAIN1[1:0]: gain / offset used in ADC single positive mode with Vinput range = 1.2V. This field also selects the gain/offset for Temperature Sensor input:: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN2 | OFFSET_GAIN2[1:0]: gain / offset used in ADC differential mode with Vinput range = 1.2V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN3 | OFFSET_GAIN3[1:0]: gain / offset used in ADC single negative mode with Vinput range = 2.4V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN4 | OFFSET_GAIN4[1:0]: gain / offset used in ADC single positive mode with Vinput range = 2.4V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN5 | OFFSET_GAIN5[1:0]: gain / offset used in ADC differential mode with Vinput range = 2.4V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN6 | OFFSET_GAIN6[1:0]: gain / offset used in ADC single negative mode with Vinput range = 3.6V. This field also selects the gain/offset for VBAT input:: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN7 | OFFSET_GAIN7[1:0]: gain / offset used in ADC single positive mode with Vinput range = 3.6V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |
OFFSET_GAIN8 | OFFSET_GAIN8[1:0]: gain / offset used in ADC differential mode with Vinput range = 3.6V: 00: OFFSET1 and GAIN1 from COMP_1 01: OFFSET2 and GAIN2 from COMP_2 10: OFFSET3 and GAIN3 from COMP_3 11: OFFSET4 and GAIN4 from COMP_4 |